X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 7.5 294.15 5% PEG 8000, 0.1 M sodium acetate, 4% glycol
Unit Cell:
a: 63.500 Å b: 92.079 Å c: 126.190 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 2.62 Solvent Content: 53.04
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION SAD THROUGHOUT 2.50 40.26 23187 1252 100.00 0.21479 0.26804 37.494
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
2.50 50.00 100.0 0.113 ? 11.8 14.3 ? 26309 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 2.50 2.59 100.0 ? ? ? 14.5 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PAL/PLS BEAMLINE 5C (4A) 0.9796 PAL/PLS 5C (4A)
Software
Software Name Purpose Version
REFMAC refinement 5.2.0019
HKL-2000 data scaling .
DENZO data reduction .
SOLVE phasing .
PDB_EXTRACT data extraction .