X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION 4.6 293.15 Prior to crystallisation, fresh sample was centrifuged at 13 000 g for 3 min to remove macro-aggregates and dust. The sample was crystallised in an anaerobic chamber filled with a N2/H2 (97:3%) atmosphere, at 20 degrees Celsius. The crystallisation was done in 96-Well MRC 2-Drop polystyrene plates (SWISSCI) containing 90 uL of crystallisation solution in the reservoir. 0.7 uL of enzyme at 6.5 mg/ml + 1 mM FAD was mixed with 0.7 uL of the crystallisation solution. The crystallisation solution contained 45 % w/v pentaerythritol propoxylate (5/4 PO/OH), 100 mM sodium acetate pH 4.6, and 400 mM potassium chloride. Prior to flash-freezing in liquid nitrogen, crystals were soaked in the crystallisation solution supplemented with 50 mM sodium nitrite for 5 min.
Unit Cell:
a: 101.760 Å b: 113.000 Å c: 135.800 Å α: 90.00° β: 90.00° γ: 90.00°
Symmetry:
Space Group: I 2 2 2
Crystal Properties:
Matthew's Coefficient: 2.8 Solvent Content: 56.17
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.20 42.02 175289 8740 73.20 0.1170 0.1427 20.51
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.20 86.86 95.1 0.067 ? 11.9 5.4 ? 175298 ? ? ?
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.205 1.326 56.9 ? ? 1.6 4.2 ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON SOLEIL BEAMLINE PROXIMA 1 1.03320 SOLEIL PROXIMA 1
Software
Software Name Purpose Version
PHENIX refinement (1.21.2_5419: ???)
PDB_EXTRACT data extraction .
autoPROC data reduction .
autoPROC data scaling .
PHENIX phasing .
Feedback Form
Name
Email
Institute
Feedback