X-RAY DIFFRACTION

Crystallization Details
Method pH Temprature Details
X-RAY DIFFRACTION ? 295 0.1 M Bis-Tris (pH 7.0) buffer containing 0.4 M NaCl and 27.5% (w/v) PEG
Unit Cell:
a: 45.860 Å b: 78.480 Å c: 85.810 Å α: 90.000° β: 90.000° γ: 90.000°
Symmetry:
Space Group: P 21 21 21
Crystal Properties:
Matthew's Coefficient: 1.91 Solvent Content: 35.45
Refinement Statistics
Diffraction ID Structure Solution Method Cross Validation Method Resolution Limit (High) Resolution Limit (Low) Number of Reflections (Observed) Number of Reflections (R-free) Percent Reflections (Observed) R-Work R-Free Mean Isotropic
X-RAY DIFFRACTION MOLECULAR REPLACEMENT FREE R-VALUE 1.81 29.10 28900 1446 99.83 0.2315 0.2591 42.75
Data Collection
Overall
Resolution Limit (High) Resolution Limit (Low) Percent Possible (Observed) R Merge I (Observed) R Sym I (Observed) Net I Over Average Sigma (I) Redundancy Number Reflections (All) Number Reflections (Observed) Observed Criterion Sigma (F) Observed Criterion Sigma (I) B (Isotropic) From Wilson Plot
1.81 29.1 99.8 ? ? 18.31 12.5 ? 28905 ? ? 34.99
Highest Resolution Shell
# Resolution Limits (Low) Resolution Limits (High) Percent Possible (All) Percent Possible (Observed) R-Sym I (Observed) Mean I Over Sigma (Observed) Redundancy Number Unique Reflections (All)
1 1.81 1.875 ? ? ? ? ? ?
Diffraction
Diffraction experiment
Crystal ID Scattering Type Data Collection Temprature Detector Detector Type Details Collection Date Monochromator Protocol
1 100 K ?
Radiation Source
Source Type Wavelength List Synchrotron Site Beamline
SYNCHROTRON PAL/PLS BEAMLINE 7A (6B, 6C1) 0.979 PAL/PLS 7A (6B, 6C1)
Software
Software Name Purpose Version
PHENIX refinement 1.21.2_5419
XDS data reduction .
XDS data scaling .
MOLREP phasing .
Feedback Form
Name
Email
Institute
Feedback